Test SB+syncs

Run SB+syncs in model, using ppcmem

PPC SB+syncs
"SyncdWR Fre SyncdWR Fre"
Cycle=Fre SyncdWR Fre SyncdWR
{
0:r2=x; 0:r4=y;
1:r2=y; 1:r4=x;
}
 P0           | P1           ;
 li r1,1      | li r1,1      ;
 stw r1,0(r2) | stw r1,0(r2) ;
 sync         | sync         ;
 lwz r3,0(r4) | lwz r3,0(r4) ;
~exists